Risk & Assurance

Pipeline Corridor Twin

Projection: today

0 of 3 segments below retirement thickness

de Waard-Milliams Sour Gas (CO₂ / H₂S) & CUI Process-Coupled Kinetics

Couples process telemetry (Temperature, pCO₂ partial pressure, H₂S sour service, and CUI insulation moisture) to dynamically recalculate wall-loss rates and RBI inspection shifts.

API 571 / de Waard-Milliams Kinetics
Process Temp82°C
CO₂ Partial Pressure1.8 bar
Sour H₂S Content180 ppm
CUI Wet Cycling35%
Segment / CircuitBaseline RateProcess-Coupled RateBaseline RULCoupled RULRBI Inspection Shift
DEMO · Jetty 1 product transfer line (DEMO-CI-JT-01)0.12 mm/yr1.39 mm/yr2.4 yr0.2 yrPull forward 26 mo
DEMO · Northern pipeline review section (DEMO-CI-PL-N01)0.12 mm/yr1.39 mm/yr12 yr1.1 yrPull forward 131 mo
DEMO · Pipeline pump manifold (DEMO-CI-PM-01)0.12 mm/yr1.39 mm/yr7.2 yr0.6 yrPull forward 79 mo

Wall-Thickness Degradation Trajectories vs. Retirement Limit

Cursor: +0y

Remaining Corrosion Allowance Matrix (% of Design Allowance)

≤0% = At or below retirement wall
Now+5y+10y+15y+20yDEMO-CI-JT-01DEMO-CI-PL-N01DEMO-CI-PM-0111%-19%-49%-79%-108%53%30%6%-17%-40%43%10%-22%-55%-88%

DEMO · Jetty 1 product transfer line · DEMO-CI-JT-01

6.02 mm / min 5.8 mm

Marine atmospheric corrosion · 0.12 mm/yr (two-point rate) · measured 2026-03-16 · DEMO · Marsden Point Terminal

DEMO · Northern pipeline review section · DEMO-CI-PL-N01

6.62 mm / min 5.2 mm

External corrosion / coating damage · 0.12 mm/yr (two-point rate) · measured 2026-03-16 · DEMO · Marsden Point–Wiri corridor

DEMO · Pipeline pump manifold · DEMO-CI-PM-01

6.82 mm / min 6 mm

Localised corrosion · 0.12 mm/yr (two-point rate) · measured 2026-03-16 · DEMO · Marsden Point Terminal

Linear projection from the last measured thickness at the two-point or engineer-override corrosion rate. Bar shows remaining corrosion allowance between nominal and retirement thickness. Not a substitute for ILI defect assessment (B31G / RSTRENG) or engineer-of-record fitness-for-service.